{"id":80344,"date":"2022-12-06T14:16:55","date_gmt":"2022-12-06T06:16:55","guid":{"rendered":"https:\/\/www.tm-robot.com\/?post_type=docs&p=80344"},"modified":"2022-12-06T14:16:55","modified_gmt":"2022-12-06T06:16:55","slug":"notice-on-calibration","status":"publish","type":"docs","link":"https:\/\/www.tm-robot.com.cn\/ko\/docs\/notice-on-calibration\/","title":{"rendered":"Notice on calibration"},"content":{"rendered":"
TMflow Software version: All versions.<\/p>\n
TM Robot Hardware version: All versions.<\/p>\n
<\/p>\n
Robot must be calibrated in accordance with standard calibration manual after replacing or disassembling joint, IO module or camera. When using Maintenance mode for calibration, select \u201cSingle Step\u201d instead of \u201cAuto\u201d. Mode \u201cAuto\u201d is used internally by Techman and is not currently available for distributor\u2019s calibration platforms.<\/p>\n